Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Clin Exp Hypn ; 68(1): 1-15, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31914368

RESUMO

Hypnotic-focused analgesia (HFA) was produced in 20 highly hypnotizable subjects receiving nociceptive stimulations while undergoing functional magnetic resonance imaging (fMRI). The fMRI pattern in brain cortex activation while receiving a painful stimulus was recorded both during nonhypnosis and during HFA. The scanning protocol included the acquisition of a T1-weighted structural scan, 4 functional scans, a T2-weighted axial scan, and a fluid attenuated inversion recovery (FLAIR) scan. Total imaging time, including localization and structural image acquisitions, was approximately 60 minutes. Without HFA, the subjects reported subjective presence of pain, and the cortex primary sensory areas S1, S2, and S3 were activated. During HFA, the subjects reported complete absence of subjective pain and S1, S2, and S3 were deactivated. The findings suggest that HFA may prevent painful stimuli from reaching the sensory brain cortex, possibly through a gate-control mechanism.


Assuntos
Encéfalo/fisiologia , Hipnose Anestésica , Manejo da Dor , Dor/fisiopatologia , Adulto , Feminino , Neuroimagem Funcional , Humanos , Hipnose Anestésica/métodos , Imageamento por Ressonância Magnética , Masculino , Manejo da Dor/métodos
2.
J Hum Hypertens ; 33(6): 421-428, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30899074

RESUMO

In affluent societies blood pressure increases with age from early life to the eighth decade with sex differences. Before middle age, lower blood pressure values are observed in women than in coeval men, whereas the reverse seems to occur thereafter. Menopause is considered the major determinant of blood pressure rise in women. If this hypothesis is well-founded, menopause can be regarded as one of the main cardiovascular risk factors, involving more than half of the human population, as well as the most ineluctable. In industrialized countries, age at menopause ranges between 50 and 52 years. The popular message is that fertile women are protected from cardiovascular risk by circulating estrogens, a privilege that is lost when postmenopausal women become not different from men from the point of view of risk factors and cardiovascular events. Nevertheless, the hypothesis that menopause or the estrogen decrease are per se associated to blood pressure increase is still under debate. Indeed, the epidemiological challenge is due to the coincidence between advancing menopause and aging, and also to the evidence that both menopause and blood pressure have common determinants such as body mass index, diet, smoking, and socio-economic class. The strongest doubt is whether menopause is a dependent or independent risk factor for high BP, i.e. whether its action on blood pressure-if any-is due directly to estrogen fall or to other indirect factors.


Assuntos
Pressão Sanguínea/fisiologia , Menopausa/fisiologia , Índice de Massa Corporal , Climatério/psicologia , Ensaios Clínicos como Assunto , Estrogênios/fisiologia , Feminino , Humanos , Pessoa de Meia-Idade , Obesidade/fisiopatologia
3.
Eur J Prev Cardiol ; 25(10): 1055-1062, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29692210

RESUMO

Background The general belief is that caffeine increases the risk of hyperkinetic arrhythmias, including atrial fibrillation. The aim of this study is to investigate the effect of chronic caffeine intake on incident atrial fibrillation in general population. Design and methods A population cohort of 1475 unselected men and women observed for 12 years and left free to intake food or beverages containing caffeine was studied. Subjects were stratified into tertiles of caffeine intake both in the whole cohort and after genotyping for the -163C > A polymorphism of the CYP1A2 gene, regulating caffeine metabolism. Results In the whole cohort, the 12-year incidence of atrial fibrillation was significantly lower in the third (2.2%) than in the first (10.2%) or second (5.7%) tertile of caffeine intake ( P < 0.001). The same trend was observed in all genotypes; the apparently steeper reduction of atrial fibrillation in slow caffeine metabolisers found at univariate analysis was proved wrong by multivariate Cox analysis. Age, chronic pulmonary disease, history of heart failure and of coronary artery disease, and systolic blood pressure - but not the genotype or the caffeine × CYP1A2 interaction term - were significant confounders of the association between incident atrial fibrillation and being in the third tertile of caffeine intake (hazard ratio 0.249, 95% confidence intervals 0.161-0.458, P < 0.01). Conclusions A higher caffeine intake (>165 mmol/day or > 320 mg/day) is associated with a lower incidence of atrial fibrillation in the 12-year epidemiological prospective setting based on the general population.


Assuntos
Fibrilação Atrial/prevenção & controle , Cafeína/administração & dosagem , Estimulantes do Sistema Nervoso Central/administração & dosagem , Fatores Etários , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Cafeína/metabolismo , Estimulantes do Sistema Nervoso Central/metabolismo , Comorbidade , Citocromo P-450 CYP1A2/genética , Citocromo P-450 CYP1A2/metabolismo , Feminino , Genótipo , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Variantes Farmacogenômicos , Polimorfismo Genético , Estudos Prospectivos , Fatores de Proteção , Fatores de Risco , Fatores de Tempo
4.
Blood Press Monit ; 23(2): 117-119, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29406326

RESUMO

The aim of this study was to determine the accuracy of the WatchBP Office ABI monitor for office blood pressure measurement over a wide range of arm circumferences using the ANSI/AAMI/ISO 81060-2:2013 protocol. The device accuracy was tested in 88 participants whose mean±SD age was 54.5±17.6 years, whose arm circumference was 30.6±8.3 cm (range: 15-46 cm), and whose entry blood pressure (BP) was 138.3±23.4 mmHg for systolic and 83.7±14.6 mmHg for diastolic BP. Four cuffs (small, standard, large, and extra-large) suitable for arm circumferences ranging from 14.0 to 52.0 cm were used. The mean device-observer difference in the 264 separate BP data pairs was 0.7±3.8 mmHg for systolic BP and was 0.0±3.7 mmHg for diastolic BP. These data were in agreement with criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). Moreover, criterion 2 was satisfied, the mean±SD device-observer difference of the 88 participants being 0.7±3.1 and 0.0±3.2 mmHg, respectively, for systolic and diastolic BP. Good agreement between observer and device was present across the whole range of arm circumferences. These data show that the Microlife WatchBP Office ABI monitor satisfied the ANSI/AAMI/ISO 81060-2:2013 standard requirements across a wide range of arm sizes.


Assuntos
Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea , Adulto , Idoso , Braço/anatomia & histologia , Braço/fisiologia , Monitores de Pressão Arterial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...